21,000 sq. ft. office and 110,000 sq. ft. warehouse, renovation circa 2011 62 tons office AC, 22 units, plus 40 tons warehouse heat, 44 – 400 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilator (ERV) Electronic night setback and ERV scheduling

Read More

8,000 sq. ft. office and 15,000 sq. ft. shop, 1-floor, new construction circa 2013 23 tons office AC, 20 tons shop heat, 11 units, 12 – 425 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilator (ERV) Electronic night setback and ERV scheduling

Read More

8,000 sq. ft. office and 15,000 sq. ft. shop, 1-floor, new construction circa 2013 23 tons office AC, 20 tons shop heat, 11 units, 12 – 425 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilator (ERV) Electronic night setback and ERV scheduling

Read More

3,000 sq. ft. office and 6,000 sq. ft. warehouse, 1-floor, new construction circa 2015 9 tons office AC, 5 tons shop heat, 4 units, 6 – 500 ft. vertical bores HDPE two-pipe hydronic piping, variable speed parallel independent pumping Internet-based energy management system

Read More

5,000 sq. ft. office and 6,000 sq. ft. shop, 1-floor, new construction circa 2016 23 tons office AC, 20 tons shop heat, 15 units, 14– 400 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Internet-based energy management system

Read More

15,000 sq. ft. office and 35,000 sq. ft. shop, 1-floor, new construction circa 2016 30 tons office AC, 108 tons shop AC, 26 tons shop heat, 43 units, 80 – 450 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilators (ERVs) Internet-based energy management system

Read More

10,000 sq. ft. office, 1-floor, new construction circa 2017 26 tons, 6 units, 16– 450 ft. vertical bores HDPE two-pipe hydronic piping, variable speed parallel independent pumping Energy Recovery Ventilator (ERV) Internet-based energy management system

Read More

10,000 sq. ft. office and 10,000 sq. ft. shop, 1-floor, new construction circa 2017 26 tons office AC, 20 tons shop heat, 11 units, 16– 400 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilator (ERV) Internet-based energy management system

Read More
Comfortworks - Comfortworks installed geothermal technology in the Van Hoose Construction Headquarters in Oklahoma City.

7,000 sq. ft. office and 4,000 sq. ft. warehouse, new construction circa 2009 14 tons, 5 units, plus 5 tons warehouse heat, 12 – 400 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy recovery ventilator (ERV) Electronic night setback and ERV scheduling

Read More
Comfortworks - Comfortworks installed geothermal technology in the Northfork Electric Cooperative building in Sayre, Oklahoma.

20,000 sq. ft. office and 13,500 sq. ft. shop, 1-floor, new construction circa 2016 56 tons office AC, 50 tons shop heat, 32 units, 53 – 400 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilators (ERVs) 3 in shop and 1 in office Internet-based energy management system

Read More