Auto/Truck Dealerships

Comfortworks - Comfortworks installed geothermal technology in MHC Kenworth in Oklahoma City.

MHC Kenworth (Oklahoma City)

17,000 sq. ft. office/showroom and 67,000 sq. ft. shop, 1-floor, new construction circa 2011 61 tons, 18 units, 54 – 250 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilator (ERV) Electronic night setback and ERV scheduling

Read More
Comfortworks - Comfortworks installed geothermal technology in MHC Kenworth in Odessa, Texas.

MHC Kenworth (Odessa, TX)

10,000 sq. ft. office/showroom and 28,000 sq. ft. shop, 1-floor, new construction circa 2012 35 tons office AC, 45 tons shop heat, 17 units, 24 – 400 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilator (ERV) Electronic night setback and ERV scheduling

Read More
Comfortworks - Comfortworks installed geothermal technology in MHC Kenworth in Topeka, Kansas.

MHC Kenworth (Topeka, KS)

10,000 sq. ft. office/showroom and 24,000 sq. ft. shop, 1-floor, new construction circa 2013 35 tons office AC, 55 tons shop heat, 19 units, 24 – 400 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilator (ERV) Electronic night setback and ERV scheduling

Read More
Comfortworks - Comfortworks installed geothermal technology in MHC Kenworth in Oklahoma City.

MHC Kenworth (Oklahoma City) Phase 2

17,000 sq. ft. office/showroom and 67,000 sq. ft. shop, 1-floor, new construction circa 2014 Phase 2 added 85 tons (9 units) of shop geothermal heat to replace waste oil heaters Tied into existing HDPE single-pipe hydronic piping and existing bore field

Read More
Comfortworks - Comfortworks installed geothermal technology in MHC Kenworth in Kingsport, Tennessee..

MHC Kenworth (Kingsport, TN)

10,000 sq. ft. office/showroom and 24,000 sq. ft. shop, 1-floor, new construction circa 2015 35 tons office AC, 75 tons shop heat, 23 units, 28 – 400 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilators (ERVs) 2 in line shop and 1 in office Internet-based energy management system

Read More
Comfortworks - Comfortworks installed geothermal technology in MHC Kenworth in Chillicothe, Ohio.

MHC Kenworth (Chillicothe, OH)

11,400 sq. ft. office and 125,000 sq. ft. shop, 1-floor, new construction circa 2016 34 tons office AC, 310 tons shop AC, 40 units, 120 – 400 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilators (ERVs) 8 in shop and 1 in office Internet-based energy management system

Read More
Comfortworks - Comfortworks installed geothermal technology in MHC Kenworth, Gainesville, Georgia.

MHC Kenworth (Gainesville, GA)

11,000 sq. ft. office/showroom and 42,000 sq. ft. shop, 1-floor, new construction circa 2016 28 tons office AC, 65 tons shop heat, 24 units, 32 – 400 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilator Internet-based energy management system

Read More
Comfortworks - Comfortworks installed geothermal technology in MHC Kenworth in Ardmore, Oklahoma.

MHC Kenworth (Ardmore, OK)

10,000 sq. ft. office/showroom and 41,000 sq. ft. shop, 1-floor, new construction circa 2016 26 tons office AC, 75 tons shop heat, 25 units, 32 – 450 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilator Internet-based energy management system

Read More

MHC Kenworth (Tye, TX)

10,000 sq. ft. office/showroom and 38,000 sq. ft. shop, 1-floor, new construction circa 2016 26 tons office AC, 65 tons shop heat, 23 units, 32 – 450 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilator Internet-based energy management system

Read More

Vance Chevrolet – Buick – GMC (Perry, OK)

7,600 sq. ft. office/showroom and 11,500 sq. ft. shop, 1-floor, new construction circa 2016 32 tons office AC, 40 tons shop heat, 15 units, 20 – 400 ft. vertical bores HDPE single-pipe hydronic piping, variable speed primary-secondary pumping Energy Recovery Ventilator (ERV) in office Internet-based energy management system

Read More